CJMWY - IN 15PA INDIUM IN-111 OXYQUINOLINE

  • MSDS: CJMWY
  • Manufacturer: NYCOMED INC
  • Product Name: IN 15PA INDIUM IN-111 OXYQUINOLINE
  • National Stock Number: -
Product Identification

Product ID:IN 15PA INDIUM IN-111 OXYQUINOLINE
MSDS Date:03/29/1993
FSC:NIIN:Submitter:F BT
Status Code:A
MSDS Number: CJMWY

Responsible Party
NYCOMED INC
101 CARNEGIE CENTER
PRINCETON, NJ 08540
US

Emergency Phone: 609-514-6400

Info Phone: 609-514-6400

Cage: 03EW0

Contractor
NYCOMED INC
PRINCETON, NJ 08540 US

Telephone: 609-514-6400

Cage: 03EW0

Ingredients

RADIOACTIVE INDIUM

CAS: 7440-74-6

RTECS: NL1050000

Fraction By Weight: 1% MCI/ML

ACGIH TLV: 0.1 MG/M3

Hazards

Routes of Entry: Inhalation:YES Skin:UNKNOWN Ingestion:YES
Health Hazards Acute and Chronic:INHALATION/INGESTION: MAY CAUSE
ASYMPTOMATIC UPTAKE IN TISSUES. EYES: MAY CAUSE MECHANICAL
IRRITATION. DATA ON BIOLOGICAL EFFECTS OF IONIZING RADIATION ARE
BASED ON EXPOSURES MUCH HIGHER THAN THOSE PE RMITTED
OCCUPATIONALLY.
Effects of Overexposure:IRRITATION
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.

First Aid

First Aid:INHALATION: MOVE TO FRESH AIR. INGESTION: ASSESS & DOCUMENT
THE AMOUNT OF ACTIVITY INGESTED. SKIN: WASH THOROUGHLY W/SOAP &
WATER/W/OTHER APPROVED DECONTAMINATION MEDIA. EYES: RINSE
THOROUGHLY W/WATER FOR 15 MINS. OBTAIN MEDICAL ATTENTION IN ALL
CASES.

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:WATER SPRAY, DRY CHEMICAL, CO2/FOAM AS APPROPRIATE
FOR THE BURNING MATERIAL.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING & NIOSH APPROVED
SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NOT CONSIDERED AN EXPLOSION HAZARD.

Accidental Release

Spill Release Procedures:ANY CLEANUP OF SPILLED RADIOACTIVE MATERIAL
SHOULD BE CONDUCTED UNDER THE DIRECTION OF SITE RADIATION SAFETY
PERSONNEL. ANY PACKAGES RECEIVED W/LEAKING INTERNAL COMPONENTS
SHOULD BE REPORTED TO MEDI-P HYSICS TECHNICAL SERVICES AT
800-832-4633. ANY PACKAGES DILIVERED IN A DAMAGED CONDITION SHOULD
BE REPORTED TO AMERSHAM ENVIRONMENTAL REGULATORY AFFAIRS AT
708-593-6300.

Handling

Handling and Storage Precautions:RADIOPHARMACEUTICALS MUST BE HANDLED
W/CARE & SAFETY MEASURES SHOULD BE USED TO MINIMIZE EXPOSURE TO
PERSONNEL. RADIOPHARMACEUTICALS SHOULD BE USED ONLY BY PHYSICIANS
WHO ARE QUALIFIED BY TRAINING & E XPERIENCE IN SAFE USE & HANDLING
OF RADIONUCLIDES.
Other Precautions:PHYSICIANS SHOULD HAVE THE EXPERIENCE/TRAINING & HAVE
BEEN APPROVED BY THE APPROPRIATE REGULATORY AGENCY AUTHORIZED TO
LICENSE THE USE OF RADIONUCLIDES.

Exposure Controls

Respiratory Protection:NOT REQUIRED UNDER NORMAL CONDITIONS.
Ventilation:LOCAL EXHAUST
Protective Gloves:DISPOSABLE RUBBER, PLASTIC/LATEX GLOVES
Eye Protection:SAFETY GOGGLES/SAFETY GLASSES
Other Protective Equipment:LAB COAT
Work Hygienic Practices:PRACTICE GOOD HOUSEKEEPING & PERSONAL HYGIENE
TO PRECLUDE THE POSSIBLITY OF CONTAMINATING WORK SURFACES,
EQUIPMENT & SKIN.
Supplemental Safety and Health
AVOID INHALING DUST/MIST; DON'T PIPETTE SOLUTIONS BY MOUTH. NO SMOKING,
EATING/DRINKING WHERE RADIOACTIVE MATERIALS ARE HANDLED/STORED.

Chemical Properties

Boiling Pt:=100.C, 212.F
Melt/Freeze Pt:=0.C, 32.F
Appearance and Odor:CLEAR LIQUID, ODORLESS

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY RELEASE
RADIOACTIVE IODINE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS.

Toxicology

Toxicological Information:ACRYLAMIDE (100%) = LD50:(DERMAL,RABBIT) 252
MG/KG. SODIUM AZIDE = LD50:(ORAL,RAT) 27 MG/KG;
LD50:(DERMAL,RABBIT) 20 MG/KG.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Regulatory

State Regulatory Information:THE STATE OF CALIFORNIA REQUIRES THAT
CUSTOMERS & EMPLOYEES ARE PROVIDED W/WARNINGS ABOUT REPRODUCTIVE &
CARCINOGENIC HAZARDS ASSOCIATED W/SUBSTANCES SOLD IN CALIFORNIA.
RADIOACTIVE MATERIALS ARE SUSP ECTED TO CAUSE REPRODUCTIVE
TOXICITY. UNDER PROPOSITION 65, THE FOLLOWING WARNING APPLIES: THIS
PRODUCT CONTAINS A SUBSTANCE KNOWN TO THE STATE OF CALIFORNIA TO
CAUSE REPRODUCTIVE TOXICITY.